Dual-Band Combiner for Co-Siting Applications 9602543X
Electrical Specifications
|
Electrical Specifications |
||||
|
Type No. |
4.3-10 Female |
96025433 Single |
96025435 Single |
96025437 Single |
|
|
|
96025434 Double |
96025436 Double |
96025438 Double |
|
Frequency Range (MHz) |
Band1 Band2 |
790-862 880-960 |
||
|
Isolation (dB) |
≥50 |
|||
|
Insertion Loss (dB) |
≤0.4 |
|||
|
Return Loss/VSWR (dB) |
≥18/≤1.3 |
|||
|
PIM3 (@2x43 dBm Carrier) (dBc) |
≤-150 |
≤-155 |
≤-160 |
|
|
Input Power (W) |
≤200 |
|||
|
Impedance (Ω) |
50 |
|||
Mechanical Specifications
|
Specifications |
|
|
Dimensions, HxWxD (excluding connectors and mounting bracket) (mm) |
Single:171x170x65 Double:171x170x106 |
|
Weight (including connectors and mounting bracket) (kg) |
Single:2.6 Double:4.5 |
|
Packing Size(mm) |
Single:350x185x228 Double:350x185x228 |
|
Color |
Light Gray (customized) |
|
Mounting |
Pole (clamps included for Ф35-135mm pole) or Wall Mounted |
Main Functions
Dual-Band Signal Combining
Efficiently combines signals from 790-862MHz and 880-960MHz frequency bands to optimize spectrum utilization.
DC/AISC Bypass Support
Provides flexible bypass configurations (Pass/Stop) for Remote Electrical Tilt (RET) and Tower Mounted Amplifier (TMA) control.
Built-in Lightning Protection
Features 8kA (8/20µs pulse) surge protection to ensure reliable operation in harsh outdoor environments.
Typical Application Scenarios
Base Station (BTS) Co-Siting
Enables multi-operator or multi-band resource sharing at cell sites, reducing infrastructure costs.
Antenna-Side Installation
Ideal for signal combining in Distributed Antenna Systems (DAS) or small cell deployments.
Indoor/Outdoor Hybrid Networks
With IP66 protection rating, suitable for both indoor equipment rooms and outdoor tower/mast installations.
Technical Features
Low Insertion Loss (≤0.4dB)
Minimizes signal attenuation to ensure high transmission efficiency.
High Isolation (≈50dB)
Effectively suppresses inter-band interference for clean signal transmission.
Superior PIM3 Performance (≤-160dBc)
Significantly reduces passive intermodulation in high-power scenarios, enhancing network quality.
Environmental Specifications
|
Environmental Specifications |
|
|
Operational Temperature (°C) |
-40 to + 60 |
|
Operational Humidity (%) |
≤95 |
|
Ingress Protection Class |
IP66 (Indoor and Outdoor) |
|
Lightning Protection |
8kA 8/20μs pulse |
Accessories (order separately)
Accessories (order separately) | |
Type No. |
Description |
50801.5519050 |
Hose clamp |