Multi-Connector Tapper 550-6000MHz 952XXXX7
|
Electrical Specifications |
||||||||
|
Type No. |
N Female |
95205087 |
95206087 |
95207087 |
95208087 |
95209087 |
95210087 |
|
|
4.3-10 Female |
95205107 |
95206107 |
95207107 |
95208107 |
95209107 |
95210107 |
||
|
7-16 Female |
95205127 |
95206127 |
95207127 |
95208127 |
95209127 |
95210127 |
||
|
Output Power Split Ratio(dB) |
2:1/3 |
3:1/4.8 |
4:1/6.0 |
6:1/8.0 |
7:1/8.5 |
10:1/10 |
||
|
Tap Loss(dB) |
J3/J2 →J1 |
-1.8 / -4.8 |
-1.3 / -6.1 |
-1.0 / -7.0 |
-0.7 / -8.6 |
-0.6 / -9.0 |
-0.4 / -10.4 |
|
|
Coupling Tolerance |
340-520 |
±1.5 |
±1.5 |
±1.5 |
±1.5 |
±1.5 |
±1.5 |
|
|
520-960 |
±1.3 |
±1.3 |
±1.3 |
±1.3 |
±1.3 |
±1.3 |
||
|
1710-4000 |
±1.0 |
±1.0 |
±1.0 |
±1.0 |
±1.0 |
±1.0 |
||
|
5300-6000 |
±1.3 |
±1.3 |
±1.3 |
±1.3 |
±1.3 |
±1.3 |
||
|
Return Loss(dB) |
≥14 |
≥15.6 |
≥18 |
≥18 |
≥18 |
≥18 |
||
|
Type No. |
N Female |
95213087 |
95215087 |
95220087 |
95230087 |
|||
|
4.3-10 Female |
95213107 |
95215107 |
95220107 |
95230107 |
||||
|
7-16 Female |
95213127 |
95215127 |
95220127 |
95230127 |
||||
|
Output Power Split Ratio(dB) |
20:1/13 |
30:1/15 |
100:1/20 |
1000:1/30 |
||||
|
Tap Loss (dB) |
J3/J2 →J1 |
-0.2 / -13.2 |
-0.1 / -15.1 |
-0.1 / -20.1 |
-0.1 / -30.1 |
|||
|
Coupling Tolerance |
340-520 |
±2.0 |
±2.0 |
±2.0 |
±2.0 |
|||
|
520-960 |
±1.8 |
±1.8 |
±1.8 |
±1.8 |
||||
|
1710-4000 |
±1.5 |
±1.5 |
±1.5 |
±1.5 |
||||
|
5300-6000 |
±1.8 |
±1.8 |
±1.8 |
±1.8 |
||||
|
Return Loss(dB) |
≥18 |
≥18 |
≥18 |
≥18 |
||||
|
Frequency Range (MHz) |
550-4000&5300-6000 |
|||||||
|
PIM3 (@2x43 dBm Carrier) (dBc) |
< -160 |
|||||||
|
Input Power (W) |
< 300(N Female), < 500(4.3-10&7-16 Female) |
|||||||
|
Peak Power (W) |
< 800(N Female), < 1500 (4.3-10 Female), < 2000 (7-16 Female) |
|||||||
|
Impedance (Ω) |
50 |
|||||||
|
Mechanical Specifications |
|
|
Dimensions, HxWxD (excluding connectors and mounting bracket) (mm) |
65.5x25x25 |
|
Weight (including connectors and mounting bracket) (kg) |
0.22 (N Female) |
|
Packing Size(mm) |
135x70x55 (30Pcs/box) |
|
Color |
Light Gray (Customized) |
|
Mounting |
Wall Mounting |
Main Functions
Precision Signal Tapping: Provides accurate coupling ratios (2:1 to 1000:1) with tap losses ranging from -0.1dB to -30.1dB (J3/J2→J1) for RF monitoring.
Multi-Band Signal Sampling: Supports dual frequency ranges (550-4000MHz and 5300-6000MHz) for 4G/5G and mmWave spectrum analysis.
High-Power Signal Handling: Manages up to ≤500W continuous input power (4.3-10/7-16 versions) with ultra-low PIM (<-160dBc).
Typical Application Scenarios
5G mmWave Base Stations: Monitors signals in 5300-6000MHz bands for beamforming calibration and network optimization.
Multi-Operator DAS: Enables non-intrusive signal sampling in shared infrastructure with precise coupling tolerance (±1.0-±2.0dB).
Broadcast Transmission Lines: Taps high-power signals (≤2000W peak) for SWR monitoring and fault detection in FM/TV systems.
Technical Features
Connector-Specific Power Handling:
N Female: ≤300W cont./≤800W peak
4.3-10 Female: ≤500W cont./≤1500W peak
7/16 Female: ≤500W cont./≤2000W peak
Frequency-Optimized Coupling:
Tight tolerance: ±1.0dB (1710-4000MHz), ±1.3dB (520-960MHz/5300-6000MHz)
High return loss: ≥14dB to ≥18dB (ratio-dependent)
Industrial Miniature Design:
Ultra-compact size: 65.5×25×25mm
Lightweight: 0.22kg (N Female version)
IP65-rated for harsh environments (-40°C to +65°C)
|
Environmental Specifications |
|
|
Operational Temperature (°C) |
-40 to +65 |
|
Operational Humidity (%) |
≤95 |
|
Ingress Protection Class |
IP65 (Indoor and Outdoor) |