Priority-Controlled Dual-Band Combiner for LTE Networks 96026778
Diplexer

Priority-Controlled Dual-Band Combiner for LTE Networks 96026778

  • Frequency Range 694-862/880-960MHz
  • Designed for co-siting purposes
  • Can be used at the BTS side or the antenna side
  • Available for various DC/AISG bypass configurations
  • Suitable for indoor and outdoor applications
  • Built-in lightning protection
  • Wall or pole mounting

    Electrical Specifications

    Electrical Specifications

    Type No.

    4.3-10 Female

    96026778

    Frequency Range (MHz)

    Band1

    Band2

    694-862

    880-960

    Insertion Loss (dB)

    ≤0.5

    Isolation (dB)

    ≥50

    Return Loss (dB)

    ≥18

    PIM3 (@2x43 dBm Carrier) (dBc)

    ≤-160

    DC/AISG Bypass

    Auto Sense

    Priority Controlled Function

    Band1

    (694-862)

     Priority 1 (highest)

     

    Band2

    (880-960)

    Priority 2 (lowest)

    Input Power (W)

    ≤200

    Impedance (Ω)

    50

    Mechanical Specifications

    Mechanical Specifications

    Dimensions, HxWxD (excluding connectors and mounting bracket) (mm)

    166x133x165

    Weight (including connectors and mounting bracket) (kg)

    4.5

    Packing Size(mm)

    335x215x260

    Color

    Light Gray (customized)

    Mounting

    Pole (clamps included for Ф35-135mm pole) or Wall Mounted

    Main Functions

    Intelligent Band Prioritization

    Automatically prioritizes Band1 (694-862MHz) over Band2 (880-960MHz) for critical traffic management

    Auto-Sense DC/AISG Bypass

    Enables plug-and-play integration with RET/TMA systems without manual configuration

    Surge Protection

    Built-in 8kA (8/20µs) lightning protection for outdoor reliability

    Typical Application Scenarios

    Public Safety LTE Networks

    Supports Band 14 (700MHz) and Band 8 (900MHz) for emergency communication

    Multi-Operator Infrastructure Sharing

    Facilitates spectrum sharing in co-located base station deployments

    Extreme Environment Deployments

    IP67-rated for operation in -25°C to +60°C with ≤95% humidity

    Technical Features

    Optimized RF Performance

    ≤0.5dB insertion loss with ≥50dB isolation between bands

    High-PIM Immunity

    ≤-160dBc PIM3 ensures clean signals in high-power scenarios

    Space-Efficient Design

    166×133×165mm chassis (4.5kg) with integrated mounting hardware

    Environmental Specifications

    Environmental Specifications

    Operational Temperature (°C)

    -25 to +60

    Operational Humidity (%)

    ≤95

    Ingress Protection Class

    IP67 (Indoor and Outdoor)

    Lightning Protection

    8kA; 8/20 μs pulse

    Accessories (order separately)

    Accessories (order separately)

    Type No.

    Description

    50801.5519050

    Hose clamp

    Send Inquiry